DOK-INDRV*-HCS02*UL
***-1803-EN-P
Bosch
Rexroth
AG
35/69
Rexroth
lndraDrive
Drive
Controllers
Power
Sections
HCS02
Instructions for Use
-
!\iJIJm@~
Dangerous
movements!
Danger
to
persons
from
falling
or
dropping
axes!
The standard motor holding brake provided or
an
external motor holding brake
controlled directly by the drive controller are not sufficient
on
their own to guar-
antee
personal safety!
Personal safety must
be
achieved using higher-level, fail-safe measures:
• Block off danger zones with safety fences or safety guards
• Additionally secure vertical axes against falling or dropping after switching
off the motor power by, for exampl
e,
mechanically securing the vertical axes
adding external braking/arrester/clamping mechanisms
ensuring sufficient equilibration of the
vertical axes
Function
The connection point X6 contains the connections for
• monitoring the motor temperature
• controlling the motor holding brake
~
Via
an
integrated contact element (BR), the power section switches
the
voltage of the
external
24V supply (connection X13 at HCS02
power sections) to the output for controlling the motor holding brake.
BR
LT
ST
int. SMPS
ZK
Fig. 5-8:
The integrated 24V control voltage supply of power sections
of
the
order code
-NxxV
is
not available at the connection point X6 (see
figure
below "Block Diagram of Internal Control Voltage"). There-
fore,
an
external
24V supply is required for controlling the motor
holding brake.
N
VI
N
V i
Br
LT
-
'--
Circuit for brake control
Power section, e.g. HCS02
Control
section, e.g. CSB01
L..--1
1"-J
l./1
1"-J
int.
ST
SMPS
(optional)
OF00024
2'101 nn.FH11
For types HCSOx.1 E-Wxxxx-NxxV: Internal switched-mode power sup-
ply
DC
bus
Block Diagram
of
Internal Control Voltage