Rexroth lndraDrive Drive Controllers
Power
Sections HCS02
PN
3
(see technical data
of
the device)
UN
3
(see technical data
of
the device)
Current carrying capacity
"looping through" from A 6
+24V
to +24V,
OV
to
OV
Continuous current
PN
3
/U
N
3
Current carrying capacity "looping through" from A 12
+24V
to +24V,
OV
to
OV
Inrush current
IE
1
N
3
Polarity reversal protection
Within the
allowed voltage range by internal protective diode
Fig.5-13: Function, Pin Assignment, Properties
Notes
on
Installation
Requirements
on
the connection to the 24V supply:
•
Minimum cross section: 1
mm
2
• Maximum allowed inductance: 100
1-JH
(2
twisted single strands, 75 m
long)
• Parallel line
routing where possible
The control voltage supply
is
routed to the connection X13 from
above: