Bosch Rexroth VT-HMC 1X Series - Demounting and replacement; Preparing demounting; Demounting the valve amplifier; Preparing components for storage or further use

Bosch Rexroth VT-HMC 1X Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30/36 Digital axis control VT-HMC...1X | Demounting and replacement
Bosch Rexroth AG, Edition 01.2021, RE 30239-B
11.2 DEMOUNTING THE VALVE AMPLIFIER
NOTICE
Electric arc and short-circuit!
Risk of destruction of system components.
Put plug-in connectors down in a way that no short-circuit fault can occur.
To demount the VT-HMC...1X, proceed as follows:
1. Disconnect connection cables and unplug connectors.
2. Loosen the latch from its snapped-in position using a screwdriver.
3. Carefully remove the VT-HMC...1X from the DIN rail while the latch is pulled
out.
Fig. 14: Removing the VT-HMC...1X from the DIN rail
11.3 PREPARING THE COMPONENTS FOR STORAGE OR
FURTHER USE
Proceed as follows in order to prepare the VT-HMC...1X for storage and further
use:
Use the original packaging for storage.
Observe the permissible storage temperature range specified in RE 30239.
Protect the axis control from dust and humidity.