NLBasic settings
Basic setting
Signal strength
Display
text
Choice
SL:00 -SL:03
Description
SL:021 Adjusting the signal
strength.
At position "SL:00" the
acoustic signal is switched
off.
If the Eco drying function is
activated, the program end
will not occur
indicated acoustically by
means of a sound signal.
Key volume bL:021 bL:00 - bL:03 Set the key volume during
operation. In position
"bL:00" the key signals are
switched off.
Efficient Dry o:021 o:00 - o:02 Activate or deactivate
automatic opening of the
appliance door during the
drying phase.
If the function is activated, the
running time may increase. The
following settings are possible:
¡When set to "o:00".
it opens automatically
of the door is deactivated
in all programs. ¡When set
to "o:01".
it opens automatically
of the door is activated
in all programs.
¡When set to "o:02".
it opens automatically
of the door is only
activated in the Eco 50°C
program.
→
"Efficient Dry", Page 12
1Factory setting (may differ depending on device type)
40