Operating instructions | 11
Open water valve.
4.3 Connect and disconnect the appliance
Connect
To start the appliance press the On/Off button.
Fig. 12
Disconnect
To shut down the appliance press the On/Off button again.
4.4 Water temperature setting
To regulate the emitted water temperature:
Press the or until the desired value is obtained.
Fig. 13
Once the desired temperature is set, open the hot water tap.
4.5 Operation
Turn ON the main swicth and the appliance is ready to work.
When a hot water tap is opened, main burner ignites and
LCD displays indication .
Fig. 14
4.6 Registration of remote control (accessory nº 7
709 003 756)
Only a qualified technician is allowed to install the additional
PCB that is supplied with the remote. Only after installation of
PCB the registration can be made.
The registration of the remote control must be done near the
appliance.
Hot water tap closed.
Turn OFF the appliance (Fig. 4, [1]).
Press and hold the programming key (Fig. 4, [3]), press ON/
OFF button (Fig. 4, [1]) to connect the appliance.
Release programming key only when LCD displays “188”
The LCD displays the signal "P2".
Press key , until it displays the signal "P3".
Press programming key again for about 1 second.
LCD panel displays one number and one rotating digit.
The number represents the remote control which is to be
registered, the first remote control will be registered with
number “0”, the second with number “1” and so on.
Check for water leaks at all joints.
The temperature value indicated on the LCD
panel corresponds to the water temperature
at the appliance outlet.
+
These appliance has an electronically
controlled gas valve that modulates the
burner input in response to both varying hot
water flow rates and/or changes in any
incoming and outgoing water temperatures.
LCD flashes until selected temperature is
reached.
6720608920-35.1AL