EasyManua.ls Logo

Bosch Therm 8000 S - Electrical Connection; Electrical Connection Guidelines; Power Cable Information

Bosch Therm 8000 S
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 720 680 174 (2014/05)Therm 8000S
Electrical connection | 27
6.4.6 Exhaustion type C
53
Fig. 44
7 Electrical connection
All regulation, verification and safety mechanisms have been
rigorously tested in the factory and are ready for use.
7.1 Connection
Connect the feed cable to an earthed power point.
7.2 Power cable
The appliance is provided with a labelled power cord and
earthed mains plug.
6720608920-29.1AL
Ø80mm Ø80mm
Ø80/125mm
Ø 135 mm est.
DANGER: Risk of electric shock!
Always disconnect the power supply to
the appliance at the mains before carrying
out any work on the electrical systems and
components.
CAUTION: Fuse protection!
The appliance should have an
independent connection to the electricity
mains, protected by a differential 30 mA
switch and be earthed. In areas subject to
frequent storms, a storm protector
should be installed.
The electrical connection should be
according to current regulations regarding
domestic electrical installations.
An earth connection is absolutely
essential.
If the power cable gets damaged it must be
replaced by a genuine spare part.

Table of Contents