8.4 Program values
This section describes details on programming the appliance.
For most applications the factory default values will provide
robust and stable operation.
CAUTION: Misadjusted program values
can lead to appliance malfunction, errors,
and service calls.
Program Description Factory default Min Max Comment
P1 Maximum Power N. Gas: 45
LPG: 39
21 N. Gas: 45
LPG: 39
See chapter 8.2.
Note: reducing P1 values below maximum
will reduce maximum power of the
appliance.
P2 Minimum Power 12 12 20 See chapter 8.2.
P3 Remote
Controls installed
_0 _0 6 See chapter 4.6.
P4 Access to
Diagnostic Mode
E0d10f See chapter 8.5.
P5 Cascade Mode nO nO CC To activate the cascade mode it's
necessary to install the “kit cascade” (cod.
7 736 500 272)
P6 Temperature Unit °C °F °C See chapter 8.5.
P7 Appliance Type Cd
(Condensing)
Cd
(Condensing)
nC Condensing / Non-condensing
note: incorrect setting will cause errors.
P8 Back light dE dE On dE: turns back light off after 60 seconds
from last button pushed.
ON: turns backlight on permanently.
P9 Fan Purge Runs secondary fan and primary fan when
P9 is selected by depressing the “P” -
button
PH Cascading type IC IC SC
This menu is only available when cascade
mode is selected CC.
PC Master/Slave mode CS CS Cn
Table 13