15
4 Technical Specifications 4
P12
Heating
Steam Electric
Other data:
Dist. throughput (DIN 11916) max. l/h(US gal/h) 120(31.7) 75(19.8)
Filter throughput l/h(US gal/h) 4000(1056) 4000(1056)
Filter surface, economy filter m
2
(ft
2
) 2.4(25.8) 2.4(25.8)
Weight without solvent: Slimline
Crossline
kg(lb)
kg(lb)
980(2161)
1080(2381)
980(2161)
1080(2381)
Weight with solvent: Slimline
Crossline
kg(lb)
kg(lb)
1300(2866)
1400(3087)
1300(2866)
1400(3087)
Floor space: Slimline
Crossline
m
2
(ft
2
)
m
2
(ft
2
)
2.3(24.81)
2.5(27)
2.3(24.81)
2.5(27)
Floor surface *** Slimline
Crossline
m
2
(ft
2
)
m
2
(ft
2
)
1.3(14)
1.3(14)
1.3(14)
1.3(14)
Cage centrifugal force N(lb) 4800(1079) 4800(1079)
Floor load Slimline
stat. and dyn. Crossline
N/m
2
(lb/ft
2
)
N/m
2
(lb/ft
2
)
13600(284)
14300(299)
13600(284)
14300(299)
Noise level dB (A) 64 64
Carbon filling, Slimsorba kg(lb) 10(22) 10(22)
Heat balance:
Heat to dissipate
via cooling water ****:
Without Slimsorba kJ/h 25000 26000
With Slimsorba ** kJ/h 26000 27000
Heat dissipated to the surroundings *:
Without Slimsorba kJ/h 9300 9300
With Slimsorba 9500 9500
* Values apply to a standard 2-bath cycle, 1
st
bath low level for distillation at cooling water inlet temperature
+ 12 °C (53.6 °F), cage housing outlet temperature 50 °C (122 °F), condensation pressure 22 bar (319
psi), 16 min. drying, 4 min. reduction, steam supply 4 – 5 bar (58 – 72.5 psi) overpressure saturated
steam, ambient temperature 5 to + 40 °C (41 – 104 °F) (with Slimsorba: 3 min. reduction, 6 min.
adsorption)
** Inc. desorption process per 25 cycles
*** Portion of the floor surface for force transmission, see Installation Instructions, Point 5.3.1
**** Refers to water without any additives
Subject to change!