Details about the type and quantity of solvent required for operation.
Lists required chemical additives for machine operation.
References to relevant literature and leaflets for technical information.
Lists applicable EC, national, and German regulations for operation.
Recommendation to use BÖWE customer service for maintenance and repairs.
Explains hazard and cautionary symbols used in the manual for safety.
Instructions for proper installation and initial startup of the drycleaning machine.
Defines the intended and authorized use of the drycleaning machine.
Guidelines for operating and maintaining the drycleaning machine safely.
Requirements and procedures for authorized personnel performing repair work.
Procedures for safely decommissioning and disassembling the machine.
Additional safety rules related to solvent handling and operating environment.
Provides a general overview of the BÖWE P 12/P15 drycleaning machine.
Illustrates and labels the components visible from the side of the machine.
Illustrates and labels the components visible from the rear of the machine.
Details fundamental operating parameters like steam pressure and temperature.
Specifies settings for the detergent solution cooler and thermal sensor.
Lists specifications for the refrigeration unit, including filling capacity and expansion valve.
Outlines settings and values for the drying process, including temperature sensors.
Specifies settings for distillation, including cooling water regulator and thermal sensors.
Procedures for the initial startup of the machine, including preparatory work.
Instructions for filling the machine with the specified drycleaning solvent.
Procedure for routine refilling of solvent into the machine.
Steps for filling the activated carbon container for the Slimsorba unit.
How to fill the water separator using specific programs.
Steps for filling the economy filter, including options for filter powder.
Procedure to prepare the integrated steam generator for operation.
Instructions on how to safely open the loading door, including emergency procedures.
Guidance on conducting a test run with garments to verify settings.
Safety precautions and record-keeping requirements for the refrigeration unit.
Instructions for adjusting and using the optional chemical dosing unit.
Information on using the SPP Spraymatic for finishing and waterproofing garments.
Procedure for filling and operating the electrically heated distillation unit.
Describes the work tank, clean tank, and optional tank 3, including their volumes.
Details the solvent pump's specifications, including delivery rate.
Explains the operation of the solvent cooling system and its settings.
Mentions the presence of a water-cooled coil in the work tank for machines without solvent cooling.
Describes the economy filter, its maintenance, and use with filter powder.
Explains the function and manual activation of the cartridge adsorption filter.
Describes the cage design for optimal airflow during drying.
Details the adjustable V-belt drive for the cage.
Explains the function of the button trap strainer for catching impurities.
Describes how the computer control system manages low and high solvent levels.
Explains the lint filter's role in catching lint and the importance of its proper use.
Describes the integration of the refrigeration unit, cooler, and pre-heater in the airshaft.
Details the refrigeration technology used for air cooling and solvent cooling.
Describes the cool-down process for guiding air and its effect on garments.
Explains the drying controller's function in regulating the drying process based on sensor temperature.
Explains the function of the machine fan during loading door operation for solvent prevention.
Describes the components of the distillation unit and its operation.
Details the overfill preventer's function and alarm messages.
Information on the emission-free system for removing still contents.
Describes the observation of distillation rates and the flow of water and solvent.
Explains the automatic dosing of chemical additives from a supply pack.
Details the Spraymatic SPP for finishing and waterproofing garments.
Explains the Slimsorba unit for reducing solvent residue and its desorption options.
Describes the safety trough that prevents solvent leaks from reaching the ground.
How to display and scroll through temperature readings on the machine.
How to view operating hours and cycle counters using specific input codes.
Steps to identify, correct, and restart the machine after a malfunction or error.
Lists all available cleaning programs with their corresponding numbers and uses.
Details the sequence and timing of operations for various programs, e.g., P1-P9.
Provides a summary of daily, weekly, monthly, and annual maintenance tasks.
Lists specific components and locations requiring maintenance attention for Slimline models.
Details maintenance for Crossline models and lists additional required checks.
Lists and describes various maintenance programs available (P9, P10/P35, P36, etc.).
Instructions for maintaining the economy filter, including filter pressure and cycle counts.
Procedures for replacing cartridges in the adsorption filter when pressure reaches 1.8 bar.
Steps for stripping the still at the end of the workday, including safety precautions.
Procedure for checking the function of the overfill sensor on the disposal vessel weekly.
Explains how to measure solvent pH and interpret the results for quality control.