20
5 Settings and Optimum Operating Values
P12 P15
Distillation:
Cooling water regulator condenser °C(°F) 45(113) 45(113)
Thermal sensor:
Cycle distillation OFF °C(°F) 135(275) 135(275)
Still stripping OFF °C(°F) 138(280) 138(280)
Still stripping OFF (electric) °C(°F) 145(293) 145(293)
Thermal sensor, distilled solvent °C(°F) 55(131) 55(131)
Panel in steam feeder mm(in) 4(0.16) 4(0.16)
Panel in direct steam line mm(in) 3(0.12) 3(0.12)
Water filling capacity in heating chamber, approx. l(US gal) 5(1.3) 5(1.3)
Pressure control switch, still (el):
ON bar(psi) 5.2(75.4) 5.2(75.4)
OFF bar(psi) 5.6(81.2) 5.6(81.2)
P12