Accessories
CT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3 = Isolated4-20mA/0-20mAAnalog Output Module
OM95-4 = Isolated1-5V/0-5VAnalog Output Module
OM95-5 = Isolated 0 - 10V Analog Output Module
OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )
OM94-7 = 14V/40mA SSR Drive Module
DC94-1 = Isolated 20V / 25mA DC Output Power Supply
DC94-2 = Isolated 12V / 40mA DC Output Power Supply
DC94-3 = Isolated 5V / 80mA DC Output Power Supply
CM94-1 = Isolated RS-485 Interface Module
CM94-2 = Isolated RS-232 Interface Module
CM94-3 = Isolated4-20mA/0-20mARetransmission Module
CM94-4 = Isolated1-5V/0-5VRetransmission Module
CM94-5 = Isolated 0 - 10V Retransmission Module
CC94-1 = RS-232 Interface Cable (2M)
CC91-3 = Programming Port Cable
CT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3
= Isolated 4 - 20 mA / 0 - 20 mA Analog Output Module
OM95-4
= Isolated 1 - 5V / 0 - 5V Analog Output Module
OM95-5
= Isolated 0 - 10V Analog Output Module
OM94-6
= Isolated 1A / 240VAC Triac Output Module ( SSR )
OM94-7
= 14V/40mA SSR Drive Module
DC94-1
= Isolated 20V / 25mA DC Output Power Supply
DC94-2
= Isolated 12V / 40mA DC Output Power Supply
DC94-3
= Isolated 5V / 80mA DC Output Power Supply
CM94-1
= Isolated RS-485 Interface Module
CM94-2
= Isolated RS-232 Interface Module
CM94-3
= Isolated 4 - 20 mA / 0 - 20 mA Retransmission Module
CM94-4
= Isolated 1 - 5V / 0 - 5V Retransmission Module
CM94-5
= Isolated 0 - 10V Retransmission Module
CC94-1
= RS-232 Interface Cable (2M)
CC91-3
= Programming Port Cable
Power InputPower Input
4: 90 - 264 VAC, 47-63 HZ
5: 11 - 26 VAC or VDC,
SELV, Limited Energy
4: 90 - 264 VAC, 47-63 HZ
5:
11 - 26 VAC or VDC,
SELV,
Limited Energy
0: None
1: RS-485
2: RS-232
3: Retransmit 4-20mA/0-20mA
4: Retransmit1-5V/0-5V
5: Retransmit0-10V
9: Special order
0: None
1:
RS-485
2:
RS-232
3:
Retransmit 4-20mA/0-20mA
4:
Retransmit 1 - 5V / 0 - 5V
5:
Retransmit 0 - 10V
9:
Special order
Communications
1: Standard Input
Input 1 - Universal Input
Thermocouple: J, K, T, E, B,
R, S, N, L
RTD: PT100 DIN, PT100 JIS
Current: 4 - 20mA,0-20mA.
Voltage:0-1V,0-5V,1-5V,
0 - 10V
Input 2 -
CT:0-50Amp. AC Current
Transformer
Voltage Input:0-1V,0-5V,
1-5V,0-10V.
Event Input ( EI )
9: Special Order
1: Standard Input
Input
1 - Universal Input
Thermocouple:
J, K, T, E, B,
R,
S, N, L
RTD:
PT100 DIN, PT100 JIS
Current:
4 - 20mA, 0 - 20 mA.
Voltage:
0 - 1V, 0 - 5V, 1 - 5V,
0
- 10V
Input
2 -
CT:
0 - 50 Amp. AC Current
Transformer
Voltage
Input: 0 - 1V, 0 - 5V,
1
- 5V, 0 - 10V.
Event
Input ( EI )
9:
Special Order
Signal InputSignal Input
0: None
1: Relay rated 2A/240VAC
2: Pulsed voltage to
drive SSR, 5V/30mA
3: Isolated
4-20mA/0-20mA
4:Isolated1-5V/0-5V
5: Isolated 0 - 10V
6: Triac Output
1A / 240VAC,SSR
C: Pulsed voltage to
drive SSR, 14V/40mA
9: Special order
0: None
1:
Relay rated 2A/240VAC
2:
Pulsed voltage to
drive
SSR, 5V/30mA
3:
Isolated
4
- 20mA / 0 - 20mA
4:
Isolated 1 - 5V / 0 - 5V
5:
Isolated 0 - 10V
6:
Triac Output
1A
/ 240VAC,SSR
C:
Pulsed voltage to
drive
SSR, 14V/40mA
9:
Special order
Output 1Output 1
9: Special order9: Special order
1: 5V Logic
Output
1: 5V Logic
Output
Alarm 1Alarm 1
1 2
3 4
5
6
0: None
1: Form A Relay 2A/240VAC
2: Pulsed voltage to
drive SSR, 5V / 30mA
3:Isolated4-20mA/0-20mA
4:Isolated1-5V/0-5V
5: Isolated 0 - 10V
6: Triac Output, 1A / 240VAC, SSR
7: Isolated 20V / 25mA DC
Output Power Supply
8: Isolated 12V / 40 mA DC
Output Power Supply
9: Isolated 5V / 80mA DC
Output Power Supply
C: Pulsed voltage to
drive SSR, 14V/40mA
A: Special order
0: None
1:
Form A Relay 2A/240VAC
2:
Pulsed voltage to
drive
SSR, 5V / 30mA
3:
Isolated 4 - 20mA / 0 - 20mA
4:
Isolated 1 - 5V / 0 - 5V
5:
Isolated 0 - 10V
6:
Triac Output, 1A / 240VAC, SSR
7:
Isolated 20V / 25mA DC
Output
Power Supply
8:
Isolated 12V / 40 mA DC
Output
Power Supply
9:
Isolated 5V / 80mA DC
Output
Power Supply
C:
Pulsed voltage to
drive
SSR, 14V/40mA
A:
Special order
Output2/Alarm2Output 2 / Alarm 2
BTC-2500-
1 2 Ordering Code1 2 Ordering Code
BTC-2500-411111
90 - 264 operating voltage
Input: Standard Input
Output 1: Relay
Output 2: Relay
Alarm 1: 5V Logic Output
RS- 485 Communication Interface
BTC-2500-411111
90
- 264 operating voltage
Input:
Standard Input
Output
1: Relay
Output
2: Relay
Alarm
1: 5V Logic Output
RS-
485 Communication Interface
SNA12A = Smart Network Adapter for
programming port to RS-232
interface
BC-Set = Configuration Software
Communicator = PC software to communicate
1024 tags
SNA12A = Smart Network Adapter for
programming
port to RS-232
interface
BC-Set
= Configuration Software
Communicator
= PC software to communicate
1024
tags
UM25001H
SNA10A = Smart Network Adaptor for Third
Party Software, Converts 255
channels of RS-485 or RS-422 to
RS-232 Network
SNA10A = Smart Network Adaptor for Third
Party
Software, Converts 255
channels
of RS-485 or RS-422 to
RS-232
Network
Example
7
Related ProductsRelated Products
Range set by front keyboard
Alternative between RS-232 and Input 2
Need to order an accessory CT94-1 if
Heater Break detection is required.
Range set by front keyboard
Alternative
between RS-232 and Input 2
Need
to order an accessory CT94-1 if
Heater