EasyManua.ls Logo

Brainchild BTC-2500 - Ordering Code

Brainchild BTC-2500
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories
CT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3 = Isolated4-20mA/0-20mAAnalog Output Module
OM95-4 = Isolated1-5V/0-5VAnalog Output Module
OM95-5 = Isolated 0 - 10V Analog Output Module
OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )
OM94-7 = 14V/40mA SSR Drive Module
DC94-1 = Isolated 20V / 25mA DC Output Power Supply
DC94-2 = Isolated 12V / 40mA DC Output Power Supply
DC94-3 = Isolated 5V / 80mA DC Output Power Supply
CM94-1 = Isolated RS-485 Interface Module
CM94-2 = Isolated RS-232 Interface Module
CM94-3 = Isolated4-20mA/0-20mARetransmission Module
CM94-4 = Isolated1-5V/0-5VRetransmission Module
CM94-5 = Isolated 0 - 10V Retransmission Module
CC94-1 = RS-232 Interface Cable (2M)
CC91-3 = Programming Port Cable
CT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3
= Isolated 4 - 20 mA / 0 - 20 mA Analog Output Module
OM95-4
= Isolated 1 - 5V / 0 - 5V Analog Output Module
OM95-5
= Isolated 0 - 10V Analog Output Module
OM94-6
= Isolated 1A / 240VAC Triac Output Module ( SSR )
OM94-7
= 14V/40mA SSR Drive Module
DC94-1
= Isolated 20V / 25mA DC Output Power Supply
DC94-2
= Isolated 12V / 40mA DC Output Power Supply
DC94-3
= Isolated 5V / 80mA DC Output Power Supply
CM94-1
= Isolated RS-485 Interface Module
CM94-2
= Isolated RS-232 Interface Module
CM94-3
= Isolated 4 - 20 mA / 0 - 20 mA Retransmission Module
CM94-4
= Isolated 1 - 5V / 0 - 5V Retransmission Module
CM94-5
= Isolated 0 - 10V Retransmission Module
CC94-1
= RS-232 Interface Cable (2M)
CC91-3
= Programming Port Cable
Power InputPower Input
4: 90 - 264 VAC, 47-63 HZ
5: 11 - 26 VAC or VDC,
SELV, Limited Energy
4: 90 - 264 VAC, 47-63 HZ
5:
11 - 26 VAC or VDC,
SELV,
Limited Energy
0: None
1: RS-485
2: RS-232
3: Retransmit 4-20mA/0-20mA
4: Retransmit1-5V/0-5V
5: Retransmit0-10V
9: Special order
0: None
1:
RS-485
2:
RS-232
3:
Retransmit 4-20mA/0-20mA
4:
Retransmit 1 - 5V / 0 - 5V
5:
Retransmit 0 - 10V
9:
Special order
Communications
1: Standard Input
Input 1 - Universal Input
Thermocouple: J, K, T, E, B,
R, S, N, L
RTD: PT100 DIN, PT100 JIS
Current: 4 - 20mA,0-20mA.
Voltage:0-1V,0-5V,1-5V,
0 - 10V
Input 2 -
CT:0-50Amp. AC Current
Transformer
Voltage Input:0-1V,0-5V,
1-5V,0-10V.
Event Input ( EI )
9: Special Order
1: Standard Input
Input
1 - Universal Input
Thermocouple:
J, K, T, E, B,
R,
S, N, L
RTD:
PT100 DIN, PT100 JIS
Current:
4 - 20mA, 0 - 20 mA.
Voltage:
0 - 1V, 0 - 5V, 1 - 5V,
0
- 10V
Input
2 -
CT:
0 - 50 Amp. AC Current
Transformer
Voltage
Input: 0 - 1V, 0 - 5V,
1
- 5V, 0 - 10V.
Event
Input ( EI )
9:
Special Order
Signal InputSignal Input
0: None
1: Relay rated 2A/240VAC
2: Pulsed voltage to
drive SSR, 5V/30mA
3: Isolated
4-20mA/0-20mA
4:Isolated1-5V/0-5V
5: Isolated 0 - 10V
6: Triac Output
1A / 240VAC,SSR
C: Pulsed voltage to
drive SSR, 14V/40mA
9: Special order
0: None
1:
Relay rated 2A/240VAC
2:
Pulsed voltage to
drive
SSR, 5V/30mA
3:
Isolated
4
- 20mA / 0 - 20mA
4:
Isolated 1 - 5V / 0 - 5V
5:
Isolated 0 - 10V
6:
Triac Output
1A
/ 240VAC,SSR
C:
Pulsed voltage to
drive
SSR, 14V/40mA
9:
Special order
Output 1Output 1
9: Special order9: Special order
1: 5V Logic
Output
1: 5V Logic
Output
Alarm 1Alarm 1
1 2
3 4
5
6
0: None
1: Form A Relay 2A/240VAC
2: Pulsed voltage to
drive SSR, 5V / 30mA
3:Isolated4-20mA/0-20mA
4:Isolated1-5V/0-5V
5: Isolated 0 - 10V
6: Triac Output, 1A / 240VAC, SSR
7: Isolated 20V / 25mA DC
Output Power Supply
8: Isolated 12V / 40 mA DC
Output Power Supply
9: Isolated 5V / 80mA DC
Output Power Supply
C: Pulsed voltage to
drive SSR, 14V/40mA
A: Special order
0: None
1:
Form A Relay 2A/240VAC
2:
Pulsed voltage to
drive
SSR, 5V / 30mA
3:
Isolated 4 - 20mA / 0 - 20mA
4:
Isolated 1 - 5V / 0 - 5V
5:
Isolated 0 - 10V
6:
Triac Output, 1A / 240VAC, SSR
7:
Isolated 20V / 25mA DC
Output
Power Supply
8:
Isolated 12V / 40 mA DC
Output
Power Supply
9:
Isolated 5V / 80mA DC
Output
Power Supply
C:
Pulsed voltage to
drive
SSR, 14V/40mA
A:
Special order
Output2/Alarm2Output 2 / Alarm 2
BTC-2500-
1 2 Ordering Code1 2 Ordering Code
BTC-2500-411111
90 - 264 operating voltage
Input: Standard Input
Output 1: Relay
Output 2: Relay
Alarm 1: 5V Logic Output
RS- 485 Communication Interface
BTC-2500-411111
90
- 264 operating voltage
Input:
Standard Input
Output
1: Relay
Output
2: Relay
Alarm
1: 5V Logic Output
RS-
485 Communication Interface
SNA12A = Smart Network Adapter for
programming port to RS-232
interface
BC-Set = Configuration Software
Communicator = PC software to communicate
1024 tags
SNA12A = Smart Network Adapter for
programming
port to RS-232
interface
BC-Set
= Configuration Software
Communicator
= PC software to communicate
1024
tags
UM25001H
SNA10A = Smart Network Adaptor for Third
Party Software, Converts 255
channels of RS-485 or RS-422 to
RS-232 Network
SNA10A = Smart Network Adaptor for Third
Party
Software, Converts 255
channels
of RS-485 or RS-422 to
RS-232
Network
Example
7
Related ProductsRelated Products
Range set by front keyboard
Alternative between RS-232 and Input 2
Need to order an accessory CT94-1 if
Heater Break detection is required.
Range set by front keyboard
Alternative
between RS-232 and Input 2
Need
to order an accessory CT94-1 if
Heater
Break detection is required.
***
***
**
**
**
*
*
*
*
*
*
*

Table of Contents

Related product manuals