3–1
3 – INSTALLATION INSPECTION
Before operating unit, be sure installa-
tion meets all requirements in the Instal-
lation Manual provided with your unit.
Follow cleaning instruc-
tions as outlined in this
manual before operating for the first
time. See “Cleaning” on page 9-1.
A remote circuit breaker or fuse should
be installed in the main power supply
located in a path of exit and clearly iden-
tified.
To avoid splashing of hot liquid, unit
must be restrained to prevent tipping.
This can be done by installing the unit in
a battery of appliances, in an alcove or
with adequate ties.
•See Safety Relief Valve on page 4-3.
DO NOT install unit where traffic areas
are on either side or behind unit.
2400GH:
Electrical Grounding
Instructions—The Model
2400GH is equipped with a three-prong
(grounding) plug to protect against
shock hazard. The plug must be plugged
directly into a properly grounded three-
prong receptacle. DO NOT cut or remove
the grounding prong from this plug.
A gas shutoff valve, installed in gas sup-
ply line, should be located in a path of
exit and clearly identified.
Gas Conversion
USA and Canada
Contact your local Broaster Company
representative for converting from one
type of gas to another.
European Union
Units manufactured for use in the Euro-
pean Union are not convertible from one
type of gas to another.
broaster.com Manual #15459 5/02 Rev: 6/15