11-5
COVER, YOKE, AND LIFT TIPS
COMPLAINT CAUSE REMEDY
Cover hard to CLOSE
1. O-ring dry or dirty
2. O-ring groove dirty
3. Hard O-ring
1. Clean and lubricate.
2. Clean.
3. Replace.
Cover will not OPEN
Never use
force to
OPEN cover.
1. O-ring dry or dirty
2. O-ring groove dirty
3. Hard O-ring
4. Pressure not released
5. Pressure regulating valve
out of adjustment
1. Clean and lubricate.
2. Clean.
3. Replace.
4. OPEN pressure regulat-
ing valve.
5. Contact service person.
O-ring Break
DO NOT rest
basket on
top flange of cooking well.
Damage to area in contact
with O-ring can cause leak-
ing under pressure or O-
ring failure.
1. O-ring groove dirty
2. Nicks in cooking well or
cover
1. Clean.
2. Remove.
Cover will not stay in raised
position
1. Weak gas spring 1. Contact service person.
Pressure Gauge does not
indicate rising pressure
when exhaust valve is
closed.
1. Port is plugged
2. Pressure gauge is dam-
aged
1. Clean port on bottom of
cover.
2. Replace pressure gauge.
broaster.com Manual #15459 5/02 Rev: 3/16A