11-2
SOLID STATE CONTROLLER TIPS
COMPLAINT CAUSE REMEDY
Display reads FAIL
1. There is a controller failure. 1. Turn cook/filter switch OFF.
Contact service person.
Display reads HI
1. Oil temperature too high. 1. Turn cook/filter switch OFF.
Contact service person.
Display reads PROB
1. There is a temperature sen-
sor probe failure.
1. Turn cook/filter switch OFF.
Contact service person.
Display reads CHEC
1. Gas valve not ON (2400GH)
2. Pilot light will not light
(2400GH)
3. Open or faulty wall fuse
4. Oil temperature not rising
properly
1. Turn ON.
2. Turn ON manual gas shut off
valve.
3. Check wall fuse or circuit
breaker.
4. Turn cook/filter switch OFF.
Contact service person.
broaster.com Manual #15459 5/02 Rev: 3/16A