11-4
GAS TIPS
COMPLAINT CAUSE REMEDY
Pilot burner will not
ignite
1. Gas valve OFF
2. Air in pilot gas line
3. Gas shut-off valve OFF
4. Incoming gas pressure too
high
1. Slide switch to ON.
2. See “2400GH LIGHTING
INSTRUCTIONS” on page 5-
3.
3. Turn ON.
4. Install regulator to control
gas pressure.
Main burner will not
ignite
1. Pilot burner not lit
2. Gas control OFF
3. Controller in program mode
4. Cook/filter switch OFF
5. Hi-limit tripped
1. See “2400GH LIGHTING
INSTRUCTIONS” on page 5-
3.
2. Turn ON.
3. Exit program mode.
4. Turn to COOK.
5. Turn cook/filter switch OFF.
Contact service person.
broaster.com Manual #15459 5/02 Rev: 3/16A