Brocade DCX 8510-8 Backbone Hardware Reference Manual 55
53-1002180-03
Determining the status of a blower assembly
4
The status for each blower assembly displays OK, Absent, or Faulty. The RPM of each fan in the
assembly is also provided. If a blower assembly displays absent or faulty, contact the Brocade
DCX 8510-8 supplier to order replacement parts. Both physically absent or faulty could also be
the result of the power supply not being properly seated.
The following figure shows the blower assembly.
FIGURE 13 Blower assembly
1Power LED 2Fault LED
TABLE 8 Blower assembly LED descriptions
LED purpose Color Status Recommended action
Power No light
(LED is off)
Blower assembly does not
have power.
Ensure that the blower assembly
is firmly seated and has power.
Steady green Blower assembly has
power.
No action required.