EasyManuals Logo

Brocade Communications Systems FCX Series User Manual

Brocade Communications Systems FCX Series
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
2 <- 3 @ 62 deg-C
MAC 1 Temperature Readings:
Current temperature : 58.5 deg-C
CPU Temperature Readings:
Current temperature : 52.0 deg-C
Warning level.......: 75.0 deg-C
Shutdown level......: 90.0 deg-C
Boot Prom MAC : 0000.0000.0720
Management MAC: 0000.0000.0720
Syntax: show chassis
Displaying Syslog messages for temperature
The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or
shutdown thresholds. The following methods describe how to view the system log on the device. If you
have configured the device to use a Syslog server or SNMP trap receiver, see the documentation for
the server or receiver.
To display the system log, enter the show log command at any CLI level.
device# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level
55.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level
45.0 C degrees
Changing temperature warning and shutdown levels
The default warning temperatures and the default shutdown temperatures for the device are:
- Warning temperature is 85 Deg-C (measured on mainboard)
- Shutdown temperature is 90 Deg-C (measured on mainboard)
NOTE
These temperatures reflect the temperature of the board inside the device.
To change the temperature at which the device sends a warning, enter a command similar to the
following at the Privileged EXEC level of the CLI:
device# temperature warning 1 85
Syntax: temperature warning stack-id value
The stack-id can be 1 - 8.
The value can be 0 - 125
device# temperature
temperature temperature sensor commands
device# temperature warning
warning Temperature at which the module sends a warning
Displaying Syslog messages for temperature
78 Brocade FCX Series Hardware Installation Guide
53-1002977-01

Table of Contents

Other manuals for Brocade Communications Systems FCX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FCX Series and is the answer not in the manual?

Brocade Communications Systems FCX Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFCX Series
CategorySwitch
LanguageEnglish

Related product manuals