Bronkhorst®
Instruction Manual EL-FLOW® Select 9.17.099F44
Capacity Unit Type Pressure
0xA158…0xA159/41305…41306
This parameter defines a reference pressure for conversion of the measured mass flow to a volume flow. See also
parameters Capacity Unit and Counter Unit.
4.8.1 Advanced fluid set parameters
Note that the parameters described in this section do not contain any actual measurement values, but only fixed reference
values, which can be used for capacity calculations, etc.
0xF168…0xF169/61801…61802
Inlet pressure of the current fluid in bar(a)
0xF170…0xF171/61809…61810
Outlet pressure of the current fluid in bar(a).
0xF180…0xF181/61825…61826
Temperature of the current fluid in °C.
0xA1A8…0xA1A9/41385…41386
Density of the current fluid in kg/m
3
0xF190…0xF191/61841…61842
Heat capacity of the current fluid in J/kg·K
0xF1A0…0xF1A1/61857…61858
Thermal conductivity of the current fluid in W/m·K
0xF1A8…0xF1A9/61865…61866
Dynamic viscosity of the current fluid in Pa·s