2-76
Confidential
Error code 9801
Error occurred with the value measured during color density adjustment performed from the
control panel.
< User Check >
- Check if the toner cartridges are set in the correct order of colors.
- Replace the toner cartridge.
- Replace the drum unit.
- If the belt unit has a scratch, replace it.
- If “WT Box End Soon” is displayed on the LCD and the belt unit has dirt, replace the waste
toner box.
Error code 9802
Dot counter or develop roller counter of color toner has reached the upper limit during color
density adjustment performed from the control panel.
< User Check >
- Replace the corresponding toner cartridge.
Calibrate
Calibration failed. Turn the power off and then back on again.
Step Cause Remedy
1 Dirt on the registration mark
sensor L
Clean the registration mark sensor L.
2 Failure in printed measurement
pattern image
If failure occurs when printing “2D3S
YMCBWKW_A” in “Function code 71”,
refer to
“4.3 Troubleshooting for Image Defects” in
this chapter and take a measure.
3 Connection failure of the
registration mark sensor L PCB
harness
Reconnect the registration mark sensor L
PCB harness.
4 Density sensor failure Replace the registration mark sensor unit.
5 Main PCB failure Replace the main PCB ASSY.
Calibrate
Calibration failed. Insufficient Toner for Calibration.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.