2-31
Confidential
Self-Diagnostic Turn the power off,
then on again.
Leave the machine for
15 min.
An error occurred in the fuser unit
when the power switch was turned
ON or sleep mode was released.
6901 2-49
Will automatically
restart within 15
minutes.
Rechecking the error after the
power switch was turned OFF and
then ON again because an error
was detected in the fuser unit.
(This message is displayed for
approximately 15 minutes when
the machine is restarted after error
code 6901 has occurred.)
6902 2-49
Service Error XX Please contact service
engineer.
Failed to authenticate the firmware
for the self test.
ED00 2-81
Failed to authenticate the NVRAM
for the self test.
EE00 2-81
Size Error Specify the correct
paper size for Tray1.
When printing from paper tray 1, a
paper size not supported for paper
tray 1 was specified from the
driver.
9702 2-72
Specify the correct
paper size for Tray2.
When printing from paper tray 2, a
paper size not supported for paper
tray 2 was specified from the
driver.
9703 2-72
Specify the correct
paper size for Tray3.
When printing from paper tray 3, a
paper size not supported for paper
tray 3 was specified from the
driver.
9704 2-72
Specify the correct
paper size for Tray4.
When printing from paper tray 4, a
paper size not supported for paper
tray 4 was specified from the
driver.
9705 2-72
Specify the correct
paper size for Tray5.
When printing from paper tray 5, a
paper size not supported for paper
tray 5 was specified from the
driver.
9706 2-72
Size Error
2-sided
Press [OK].
Specify the correct
paper and load the
same size paper as
the Printer driver
setting.
A tray set to duplex printing-
incompatible size was specified in
duplex printing.
9701 2-72
Specify the correct
paper.
The registration rear sensor
detected that the paper fed was
smaller or larger than the specified
size in duplex printing mode.
8A01 2-65
Error message
Description
Error
codes
Refer
to:
First line Second line