EasyManua.ls Logo

Brusa DMC524 - Connections; Circuit Connections

Default Icon
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
and startup
38
8 Connections
8.1 Circuit connections
INFORMATION
For connections 1 - 5 the following specifications are recommended:
Shielded, insulated automotive cable (e.g. Huber & Suhner).
Cable lug without insulation for each M8 cross section (e.g. Vogt AG).
Torque for cable lug (M8 x 10): 15 Nm.
1.
High voltage- (HV-)
2.
High voltage+ (HV+)
3.
Motor phase U
4.
Motor phase V
5.
Motor phase W
6.
Control connector
(Chapter 8.3 Pin assignment of control connector)
7.
Motor sensor connection
(14 pole low voltage)
(Chapter 8.2 Pin assignment motor sensor
connection)
8.
Grounding screw
(Chapter 8.5 Grounding screw)
9.
Cooling water outlet
(Chapter 8.6 Cooling water connections)
10.
Cooling water inlet
(Chapter 8.6 Cooling water connections)