7 – 32 Repair manual SWE100, 120, 120L, 120S, 140, 140L, 200D © BT
Troubleshooting
Digital input/output status
T code Valid from serial no. Date Order no.
841×842×843 6061850- 2012-08-30 258946-120
7.8 Digital input/output status
7.8.1 Test function “9” – Transistor regulator
In this setting, the digital inputs and outputs are tested by checking
specific segments on the display according to the following tables.
Position:
1 and 2: The transistor regulator's current value. What is the current
value in each input/output.
3 and 4: The transistor regulator's set point. Relating to what the
software value should be.
A – H: Reference to segment
One or more segments may be lit continuously at each position. The
indications can also be combined across several positions.
[xxx] in the table is the component designation
{nn} in the table is the wiring number in the electrical wiring diagram.
11 Maximum value registered by the collision
sensor (option)
Min.: 0
Max: 100
12 Status of inputs/outputs, expansion unit 1
(optional)
-
13 Status of inputs/outputs, expansion unit 2
(optional)
-
Mod
e
Flashing symbol Data shown in the display Normal value
A
B
C
D
E
F
G
H
1234