Functions and parameters
Parameters
© BT Repair manual  SWE100, 120, 120L, 120S, 140, 140L, 200D 6 –   13
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
6.5.5 Service parameters
Note:
Changing specific truck parameters changes the truck's driving 
properties. Do not change any parameter values without the 
necessary know-how.
Note:
Parameter 201 must be set to a value equal to or larger than the value 
of parameter 5. If a value of any parameter is changed causing the 
value of parameter 201 to become smaller than that of parameter 5, 
then the value of parameter 201 will automatically be reset to 100. 
When this parameter value is changed automatically, error code 2.002 
is generated.
Note:
Make sure that service parameter 109 is set to the value for the battery 
that is fitted, and that the correct battery capacity is set in parameter 
110. 
Note:
For Hawker Evolution batteries only the battery sizes 134Ah, 174Ah 
and 201Ah may be used. 
Before any service parameter can be adjusted, the CAN service key 
must be connected to the connector [X41].
Param
eter
Designation/
unit
Min./
Max.
Incr
eme
nt
Def
ault
Description
101 Service interval, 
hours
0/
2000
50 0 Specifies a limit when the next service 
should take place. Error code 2.003 is 
displayed when it is time for service.
0 = Service prompting switched off.
102 Operator 
access
1/10 1 3 Determines the log-in method to be used 
and whether the operator should be able to 
change operator parameter settings.
Values 1 and 2 = Key
Values 3 and 4 = Keypad with 100 PIN 
codes
Values 5 and 6 = Keypad with DHU
Values 7 and 8 = ID unit
Values 9 and 10 = ID unit with DHU
Odd values = Open operator parameters
Even values = Operator parameters can 
only be changed with a CAN key.
103 Hour counter 
option
1/5 1 2 Determines a time value for the hour 
meter.
Fore more information, see the Hour meter 
section in this chapter.
https://www.besttruckmanuals.com/