BTU VENTILATION CORPORATION OFFICE 888-884-8070 FAX 218-346-7485
www.btucorp.com
XT-70 Control Panel 6
XT Analog Inputs:
Plenum 1 F 2250 ohm
Plenum 2 F 2250 ohm
Outside Air F 2250 ohm
Return F 2250 ohm
Pile 1 F 2250 ohm
Pile 2 F 2250 ohm
Pile 3 F 2250 ohm
Pile 4 F 2250 ohm
Pile 5 F 2250 ohm
Pile 6 F 2250 ohm
Pile 7 F 2250 ohm
Pile 8 F 2250 ohm
Outside Humid % 4-20mA
Plenum Humid % 4-20mA
Return Humid % 4-20mA
CO2 ppm 4-20mA
XT Digital Inputs:
Fan proving Dry contact
Cell pump proving Dry contact
Refrigeration Fail Dry contact
Remote Standby Dry contact
Spare
Spare
Spare
Spare
Low Temp SPDT contact
Air Restrict Dry contact
Start / Stop Dry contact
XT Sensors: The XT panel can accept a number of different input sensors and has ten solid state 3
amp outputs. In addition, there are two analog outputs that are 0-20mA or 0-10VDC. The fresh air
doors are controlled by two relay outputs.
XT Analog Outputs:
Freq Drive 0-20mA / 0-10VDC
Refrigeration 0-20mA / 0-10VDC
XT Digital Outputs:
Red light 3A 120VAC SS
Yellow light 3A 120VAC SS
Fan / Green light 3A 120VAC SS
Evap cooling pump 3A 120VAC SS
Humidifier pump 1 3A 120VAC SS
Humidifier pump 2 3A 120VAC SS
Heater 3A 120VAC SS
Aux 1 3A 120VAC SS
Aux 2 3A 120VAC SS
Cavity heater 3A 120VAC SS
Door open 12VDC/relay
Door close 12VDC/relay
Note - The Aux 1, Aux 2, and cavity heater can be set to be interlocked with the Start / Stop
switch, mechanical Low Temp and Air Restriction devices or to operate independently.