AXIOM
®
Training Manual
10
Allows the testing of individual components and the ability to check the membrane
switches for proper function.
Reset all of the previously entered brew settings, ad message, calibrations, etc.
Level 3 Programming
To access Level 3 programming press and hold the right hidden button, until the screen reads Cal. Temperature,
while on the Enter Password screen in Level 2 of programming.
This function allows the operator to “recalibrate” the CPU to the temperature thermistor.
This must be preformed when you replace a CPU or a thermistor.
This function allows for automatic adjustment of brew cycle times based on the output of
the sprayhead.
This function is used for calibration of the water volumes from the long level probe to the
short level probe.
Thisisusedtotelltheinternalcontrollerhowfastthewaterisowing.
This function provides a 60 second test mode to capture water from the sprayhead. This
measurement will then give you the numbers to enter into the “SPRAY OZ/M: xx” screen
above. Will not display when BrewLOGIC
®
is enabled.
Machine Setup
Brew Oz.
It is necessary to setup the desired Brew Oz., due to the different size containers available in the market.
To convert liters to ounces use this simple math equation.
Liters X 33.9 = ounces
For example if you were using a 3.0L airpot this is what your equation would look like.
3.0 X 33.9= 101.7 rounded up to 102 uid US ounces.
Step 1: Enter programming Level 1, (BrewWIZARD
®
).
Step 2: Scroll to the Brew Oz. screen.
Step 3: Use the (-) or (+) to enter Oz. the desired ounces for the container to be used.
SERVICE TOOLS ?
NO YES
FACTORY DEFAULTS
NO YES
CAL TEMPERATURE
NO YESSENSOR?
% Lime Adjust OFF
(-) (+)DONE
LP1 LP2 OZ 4.50
(-) (+)DONE
SPRAY OZ/M: 25.0
(-) (+)DONE
CALIBRATE FLOW ?
NO YES
BREW OZ: 64.0
(-) (+)DONE