Bunn Axiom Series - Preventive Maintenance; PM Steps

Bunn Axiom Series
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AXIOM
®
Training Manual
20
Preventive Maintenance
In order to maintain proper operation and long service life BUNN
®
recommends performing the preventive main-
tenance every 6 months. Individual customers will vary with some customers choosing not to receive preventive
maintenance.
Tools Required:
• 2 Flat head screwdrivers (1 small, 1 medium)
• Adjustable wrench
• Needle nose pliers
• Deliming tool (BUNN P/N: 38227.0000)
Prior to servicing the brewer:
• Disconnect the electrical supply
• Shut off water supply
PM Steps
Step 1: Remove probes from tank lid.
Remove top and front access panels
Drain tank using drain hose located behind front panel. Caution Hot Water!!
Remove thermistor probe (temp probe) from the top of the tank. Clean and inspect
Remove liquid level probes (2) from tank lid clean and inspect
Reassembly is the opposite of disassembly
Step2:Rebuildbrewvalve,cleanoutletttingsattank.
Remove wire leads from brew valve
Carefully remove silicon hose from brew valve
Remove mounting nuts
Remove 4 screws from valve
Replace plunger, spring and rubber seat using rebuild kit, (BUNN P/N: 11517.0008)
Carefullyremovethesiliconhosesfromtheoutlettankttings
Cleanttingsusingdelimingtool(longend)orsuitabletool
Reassembly is the opposite of disassembly
Step 3: Rebuild hot water faucet.
Replace hot water seat cup by unscrewing the bonnet assembly
Remove old seat cup
Install new seat cup, (BUNN P/N: 02766.0000)
Reassembly is opposite of disassembly
Step4:CleanandinspectSprayheadcleansprayheadtting.
Clean and inspect Sprayhead
CleanSprayheadttingusingdelimingtool
Step 5: Inspect brew funnel for missing or loose parts.
Step 6: Inspect water connection points for signs of leakage.
Step 7: Inspect power cord.
Step 8: Return AXIOM
®
to service.
Turn on water supply and check for leaks
Plug AXIOM
®
in at wall receptacle
Allowtanktollandheattooperatingtemperature