7.8.11 Logging to a file in internal memory
If enabled, the system will keep logs of the last 31 days. These logs can be accessed
through the web remote.
An example section from a log file is shown below:
2016-04-22 11:40:06
DTLG > M: exciter_locked = 1
DTLG > M: peak_deviation = 75kHz
DTLG > M: fwd_power = 250W
DTLG > M: rev_power = 3W
DTLG > M: pa_voltage = 30.1V
DTLG > M: aux_voltage = 15.1V
DTLG > M: pa_temp = 30.0*C
DTLG > M: cpu_temp = 25.0*C
DTLG > M: tx_input_l = -21dB
DTLG > M: tx_input_r = -21dB
DTLG > M: agc1 = 0dB
DTLG > M: agc2 = 0dB
DTLG > M: agc3 = 0dB
DTLG > M: agc4 = 0dB
DTLG > M: lim1 = -22dB
DTLG > M: lim2 = -6dB
DTLG > M: lim3 = -6dB
DTLG > M: lim4 = -6dB
DTLG > M: tx_output_l = -6dB
DTLG > M: tx_output_r = -8dB
DTLG > M: tx_output_mpx = 20dB
DTLG > P: transmitter.frequency = 98.00MHz
DTLG > Alarm status [3-0]: Off Off On Off
DTLG > Trigger status [3-0]: On On On On
7.8.12 Diagnostics
This set of parameters report the state of various parts of the system upon boot (OK or
fail). If an error condition is observed, the unit should be re-booted and these
parameters should be examined. This information will be useful when contacting
support.
7.8.13 About
The about menu contains the version numbers of the different parts of the system. These
values should be available when contacting support.