7.10 Text Based Access (Telnet or RS232)
The unit offers text based access via a local network or the internet through Telnet or
serial RS232.
7.10.1 Commands
The following commands are available:
help This command (without any arguments) displays a list of the
commands the unit understands.
help parameter_id This command displays a short description of the requested
parameter, e.g. V3> help transmitter.power will return:
V3>transmitter.power (Sets the output power level in watts.
This parameter accepts values from 0 to 600.)
get parameter_id
This command returns the current value of the parameter
requested. e.g. V3> get transmitter.frequencywill return:
V3> 98.00MHz
set parameter_id parameter_value
This command sets the parameter requested to the value
specified. e.g. V3> set transmitter.power 150OK
reboot This command reboots the unit.
Please note - there will be no confirmation stage, if you send this command the unit will
reboot immediately, taking your transmitter temporarily off-air.
FactoryReset
This command resets all values to their default apart from the Ethernet
settings of the unit.
As above, there is no confirmation required, the action is immediate.