You have purchased a product that is durable and
easy to service. However, all technical equipment
requires regular servicing to guarantee optimal
functionality.
Regularchecksofthelterbytheoperatorarere-
quired to ensure the warranty conditions and proper
functioning of the unit.
The operator must perform a visual check and
backwashtheltertoguaranteefunctionalityand
fullthewarrantyconditions.AdditionallyforHWS:
Checktheoutputpressureevery2monthswhen
thereisnoowandwhenlargequantitiesofwater
aredrawno󰀨.
According to DIN EN 806-5, the filter must be
checkedfor leaks and dirt everysix months and
backwashed at regular intervals, which may depend
onoperatingconditionsbutbenolongerthansix
months.
 
The replacement of wearing parts within the prescri-
bed maintenance intervals is also required for the
warrantyandproperfunctioning of the unit.Only
qualiedtechniciansmayreplacewearingparts.
 
Checkforleaks,visualinspection Weekly
Checktreatedwaterquality Monthly
 
Flat gasket every 3 years
Stopper every 3 years
Filter element every 6 years
Backwashelement(repairkit) every 6years
Solenoid valve every 9 years
Oring(inbayonet) every 15years
Transparent cylinder every 15 years
We recommend that you conclude a maintenance
contract with your plumber.
 
  
Water pressure dropped
considerably in network
Dirtylterelement Carryoutbackwash
Flushing water outlet
does not close
Backwash element does not
reach the end position due to
large particles of dirt
Scalingattheventtube(5)
Repeat backwash several times
Unscrew wastewater connection
(6)andcleanventtube(5)outside
InnityAPonly:
Display shows 
Pressuretoolow Repeat backwash several times.
Increase pressure
If the fault cannot be remedied by following these tips, contact our after-sales service department.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BWT Infinity A+AP and is the answer not in the manual?

BWT Infinity A+AP Specifications

General IconGeneral
BrandBWT
ModelInfinity A+AP
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals