32
EN
2"
Nominal connection width DN 20 25 32 40 50
Throughputat∆p=0.2bar m
3
/h 4 5 5.5 10 10
Throughputat∆p=0.5bar m
3
/h 7 7.5 9 16 16
Outputpressuredownstreamof
pressure reducer with connec-
ting module or connection piece
bar 2,5
Lower/upper admission width µm 90 / 110
Nominalpressure(PN) bar 16
Operatingpressure,
min./max.
bar 2.5 during backwashing / 16
Water / ambient tempera-
ture,min./max.
°C 5 - 30 / 5 - 40
Powersupply V/Hz 230/50/60(unitoperationat24V-)
Powerconsumptionduring
backwashing
W 8
AP:CICdrycontact,swit-
ching capacity
max.24V/1A(resistiveload)
Connectiontype Hydromodul-connection Four-holeange
Thetypelabelservesasproductidentier.Incase
of any requests, please have the following infor-
mation ready:
1. Device name
2. Serial number / Year of manufacture
3. Productionnumber/Order-no.
Thetype label is an ocial document and
mustnotbe altered orstrippedo. Dama-
ged or unreadable type labels have to be
replaced.
2
3
1