CONSTRUCTION & REENOVATION 31 2022/12 - Indice de révision : D - Code : 32570
11. Prolonged shut-downs/ winterizing
In the case of passive winterizing (complete shutdown of the pool, draining of equipment in the plant room and
lowering of the water level in the pool), trip the switch at the head of the panel’s power line.
In the case of active winterizing, leave the panel in operation, filtration set to automatic mode, but shorten the
daily filtration period so that it only runs 2 to 3 hours per day. Take care to divide the total filtration time into at
least 3 cycles, and if possible, program 2 at night (one at the beginning the other at the end of the night) when
the risk of freezing is highest.
In the event that outdoor temperature approaches 0°C in the middle of the day, lengthen the daily filtration period.
For indoor pools that are used year round, do not modify the settings.
12. Troubleshooting
Error message Solution
Your filtration panel has been stopped for
maintenance
Press the button on the housing down for 10 seconds
Buffer tank low level warning:
Check the water level
Add water to the pool
Buffer tank high level warning:
Check the water level
Lower the water level in the buffer tank
Your filtration pump has been stopped for over 24
hours
Switch filtration to automatic mode
Check that operating times have been programme if
timer mode is selected
Your filtration pump has been running for 48 hours
Switch filtration back to automatic mode
Check that operating times have been programme if
timer mode is selected
Clogging warning: perform a backwash of your
filter
Perform a backwash of your filter
"Auxiliary 1 name" has been running for 24 hours Stop the auxiliary or run it in automatic mode
"Auxiliary 2 name" has been running for 24 hours Stop the auxiliary or run it in automatic mode
"Auxiliary 3 name" has been running for 24 hours Stop the auxiliary or run it in automatic mode
"Auxiliary 4 name" has been running for 24 hours Stop the auxiliary or run it in automatic mode
"Auxiliary 5 name" has been running for 24 hours Stop the auxiliary or run it in automatic mode
Your underwater light has been on for over 12
hours
Turn off your underwater light, switch it rather to
automatic mode
Temperature sensor not connected
Connect the temperature sensor or replace the
sensor