Technical manual BWT PERLA PRO XS - code P0011650B - Rev 7 - 26/10/2021
25
hose
INSTALLATION
Hoses In/Out mandatory
Clamps
It is under the installer’s responsibility to make sure that the installation does not generate any water
hammer which could damage the proper work of the softener.
Our softeners are equipped with a check valve on the water inlet connection flange. The check valve may
exit the flange under extreme operating and mounting conditions. To avoid this phenomenon, it is
mandatory to connect the softener with flexible hoses (according to diagram here below).
CAUTION : Do not insert a reduction or an adapter between the softener connection flange and the
flexible hose. The flexible hose of the same diameter as the flange must have a gasket that keeps the
check valve locked in its housing.
INLET WATER
gasket
check valve
flange of the softener (inlet)