iNetVu™ Service Manual Page 50 of 109
STOW Button on iNetVu™ Controllers
The STOP/STOW push button is located on the front panel of the iNetVu™
5000/7000/9000 Controller.
Hold down the STOW button for 5 seconds and release. This will allow the iNetVuTM
Platform to automatically move to the stowed position.
iNetVu™ Mobile Software Manual Controls
1) If you are using a 5000 or 9000 Controller, advance to the configuration menu,
and switch to CONFIG mode.
2) Go to Maintenance and click Advanced.
3) Disable ALL limits and click Send.
4)
Go to Advanced Controls
5) Set Duration to 50.
6) Use the manual control buttons to move the dish to the physical stow position in
the following order.
a. Polarization
b. Azimuth
c. Elevation (Set the Duration to 10 for better control)
Turn Off the iNetVuTM Controller once the antenna is completely stowed, and contact a
C-Com Satellite Systems Inc. Technical Support Representative.