EasyManua.ls Logo

Cafection Encore VENTI - SERVICE MODE OPERATIONS; User Levels and Access Permissions

Cafection Encore VENTI
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENCORE VENTI Rev. 3 2021-10
33
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Cafection's Encore Venti
6 SERVICE MODE
6.1 Users Levels
Level1: For the end user. Beverages selection and ordering only. Level1 users cannot access the
brewer’s settings.
Level2: For service personnel. Basic maintenance (no password required).
Level3: For service tasks. Recipes modification and system settings access. Level3 users have
access to all tabs and sub tabs in Service mode, with the exception of the Audits tab and the
Admin sub tab.
Factory password for this level: tech
Level4: For administrative tasks. Sales counters (audits) access and passwords modification.
Level4 users have access to all tabs and sub tabs in Service mode.
Factory password for this level: admin
Cafection highly recommends changing those passwords.
To access Service mode, open the brewer’s door and press on the SW2 button (white) on the main
board (see section3.6).
Service Mode
Access Levels:
2 2 3 3 3 4