VOYANT ALIMENTATION
PRINCIPALE
DISJONCTEUR
COMMANDE
MONITEUR DE PHASES
CONTACTEUR
(COMP2)
DISJONCTEUR
(COMP 2)
BORNES D'INTER
VERROUILLAGE
VOYANT DEFAUT
PRESSOSTAT HP
DEMARRAGE AMORTI DISJONCTEUR
THERMIQUE ET VOYANT
DE DEFAUT SI INSTALLE
DEMARREUR OU
CONTACTEUR DE DEBIT
PRESSOSTAT BP
PROTECTION ELECTRONIQUE
COMPRESSEUR 2
VEILLE
COMMUTATEUR
COMMUTATEUR
DEBIT D'EAU
PROTECTION ELECTRONIQUE
COMPRESSEUR 1
RECHAUFFEUR
COMPRESSEUR
RECHAUFFEUR
COMPRESSEUR
VOYANT DEBIT D'EAU
3 N/F (VEILLE)(O)
2 N/O (MARCHE)(I)
(COM) C
(N/F) L
THERMOSTAT
DEGIVRAGE
10 (SECS)
NEUTRE
DISJONCTEUR
(VENTILATEUR)
VENTILATEUR
RELAIS (R3)
COMP
2
TEMPORISATION T3
(N/O)
RELAIS (R2)
TEMPORISATION T1
(12 HEURES)
VOYANT
TEMP OK
A
RELAIS (R1)
CONTACTEUR
(VENTILATEUR)
(N/F) 1
(N/F) 3
VOYANT
REFROIDISSEMENT
SOUPAPE D'INVERSION
VOYANT CHAUFFAGE
PRESSOSTAT ET
VOYANT LIMITE DE
REFROIDISSEMENT
VOYANT
DEGIVRAGE
COMP
1
TEMPORISATION
T2 (6 MINS)
COMP 1 MCB AUX
COMP 2 MCB AUX
63
64 (N/O)
63
64 (N/O)
(COMP 1)
CONTACTEUR
DISJONCTEUR
(COMP 1)
THERMOSTAT - 2 CANAUX
CONTACT 7 ET 8 FERMES EN MODE FROID
CONTACT 6 ET 4 FERMES EN MODE CHAUDE
SONDE
ELECTROVALVE
(ARRET LIGNE
LIQUIDE)
H (N/O)
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
(SE COUPE A H EN
BASSE TEMPERATURE)
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
L3 L2 L1
L3
L2
L1
14 (N/O)
12 (N/F)
11 (COM)
CONTACT ALARME DISJONCTEUR
VENTILATEUR
CONTACT ALARME
DISJONCTEUR COMP 2
CONTACT ALARME
DISJONCTEUR COMP 1
5
3
1
6 (N/O)
4 (N/O)
2 (N/O)
96
95 (N/F)
95
96 (N/F)
(N/F)
C (COM)
H (N/C)(N/O) L
C (COM)
H (N/O)
(N/C) L
(SE COUPE A 'L EN
HAUTE PRESSION)
(SE COUPE A 'H' EN
BASSE PRESSION )
(N/O)
A
B
(COM) 1
(COM) 6
4 (N/O)
11
10
5
3
1
6 (N/O)
4 (N/O)
2 (N/O)
(N/O) 11 14 (COM)
21 22 (N/F)
A1
A2
(W)
(V)
(U)
5 (N/F)
4 (N/O)
1 (N/F)
(COM) 7
(COM) 15
18 (N/O)
16 (N/F)
A1 A2
(COM) 7
8 (N/O)
9 (N/F)
2 (N)
C (COM)
H (N/O)
(N/F) L
OUT
1 OUT 2
A
B
A2A1
A1
A2
7 (COM)
(N/O) 4
9 (COM)
(N/O) 6
(SE COUPE A H EN BASSE
DE TEMPERATURE)
1 (L)
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
21 22 (N/F)
(W)
(V)
(U)
A1
A2
18 (N/O)
(COM) 15
A2A1
54 53 (N/O) 54 53 (N/O)
16 (N/F)
COMP 1 CONT AUX
COMP 2 CONT AUX
(N/F)
95
96 (N/F)
(NF)
TK
TK
PROTECTION THERMIQUE
VENTILATEUR
CIRCUIT
2.5A
VALEURS DISJONCTEUR
COMPRESSEUR VENTILATEUR
2.8A23.8A
PP(T)70BHC TRIPHASEE (400V ~ 3 N 50Hz)