EasyManuals Logo

CAME GARD 8 SERIES Installation And Operation Manual

CAME GARD 8 SERIES
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
UNI6954 Ø 3.9x19
p.
10
10 - Manual code:
FA01036-EN
FA01036-EN v.
1
- 01/2018 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Fit the anti-shearing protective cover onto the boom-attachment cover and fasten it with screws.
400 mm PASSAGE CLEARANCE (max. 7.60 m)
Balancing the boom
Before balancing the boom, check on the table below for congruences between the chosen spring, accessories and passage clearance.
⚠
WARNINGS!
001G02802 Cannot be used on barriers fitted with the 001G0465 skirt or 001G02808 swing rest
001G02808 For passage width clearances of up to max. 7 m.
001G02807 MUST be used with passage width clearances of over 7 m.
001G0465 - 001G02808 Cannot be used together.
The boom includes the transparent groove cover and end cap.
A
Spring 001G02040 Ø 40 mm
B
Spring 001G04060 Ø 50 mm
C
Spring 001G06080 Ø 55 mm
BOOM LENGTH (m)
2 ÷ 2.5 2.5 ÷ 3 3 ÷ 3.5 3.5 ÷ 4 4 ÷ 4.5 4.5 ÷ 5 5 ÷ 5.5 5.5 ÷ 6 6 ÷ 6.5 6.5 ÷ 7 7 ÷ 7.6
Boom
A A A A A B A B A B B B B B B C C C
Boom with swing-leg 001G02808
A A A A A A A B A B B B B B B C C C
Boom with luminous cord 001G28401
A A A A A A A B A B B B B B B C B C C C
Boom with 001G02808 swing rest and 001G28401
luminous cord
A A A A A B A B B B B B B C C C C C
Boom with skirt 001G0465
A A A A B A B B B B B B C B C C C
Boom with 001G0465 skirt and 001G028401
luminous cord
A A A A A A B A B B B B B B C C C C C

Other manuals for CAME GARD 8 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME GARD 8 SERIES and is the answer not in the manual?

CAME GARD 8 SERIES Specifications

General IconGeneral
ModelGARD 8 SERIES
TypeAutomatic Barrier
Motor voltage24 V DC
Power300 W
Operating temperature-20°C to +55°C
Protection ratingIP54
Input Voltage230 V AC
Output Voltage24 V DC
Protection DegreeIP54
Power supply230 V AC
Opening time4 to 8 seconds