EasyManuals Logo

CAME GARD 8 SERIES Installation And Operation Manual

CAME GARD 8 SERIES
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
~1°
~89°
+
-
~1°
~89°
+
-
p.
15
15 - Manual code:
FA01036-EN
FA01036-EN v.
1
- 01/2018 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
To correct the horizontal position:
- raise the boom;
- turn the mechanical closing stop clockwise to increase the boom travel or counter clockwise to reduce it .
Fasten the stop with a counter nut .
Establishing the endstop points
Close the inspection hatch and power up the system. Activate the barrier to check whether the boom is parallel to the road surface when close
and at about 89° when open.
The boom's opening and closing maneuvers must be performed with the inspection hatch closed.
To correct the boom's vertical position:
- lower the boom;
- open the inspection hatch;
- turn the opening mechanical stop clockwise to increase the boom's travel or counter clockwise to reduce it .
Fasten the stop with a counter nut .

Other manuals for CAME GARD 8 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME GARD 8 SERIES and is the answer not in the manual?

CAME GARD 8 SERIES Specifications

General IconGeneral
ModelGARD 8 SERIES
TypeAutomatic Barrier
Motor voltage24 V DC
Power300 W
Operating temperature-20°C to +55°C
Protection ratingIP54
Input Voltage230 V AC
Output Voltage24 V DC
Protection DegreeIP54
Power supply230 V AC
Opening time4 to 8 seconds

Related product manuals