Standard installation
1. Operator
2. Arm
3. Opening radar
4. Safety radar
5. Touch sensor
6. Microphotocells
7. Features selector
Tools and materials
Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable
regulations. The figure shows some of the equipment installers will need.
Cable types and minimum thicknesses
Connection Cable type
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Control panel power supply 230 V AC
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1.5 mm
2
3G x 2.5 mm
2
3G x 4 mm
2
Photocell transmitters 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Photocell receivers 4 x 0.5 mm
2
4 x 0.5 mm
2
4 x 0.5 mm
2
Command and safety device 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw
of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the
actual power draw and distances. If connecting products that are not contemplated in this manual, see the literature
accompanying said products

Other manuals for CAME PB1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME PB1100 and is the answer not in the manual?

CAME PB1100 Specifications

General IconGeneral
BrandCAME
ModelPB1100
CategoryGate Opener
LanguageEnglish

Related product manuals