Questions and Answers

  • T
    Teresa HughesSep 10, 2025
    Why does the PROGRAMMING LED stay lit on my CAME Gate Opener?
    • M
      Marcus ShepherdSep 12, 2025
      If the PROGRAMMING LED stays lit on your CAME Gate Opener, it could be due to using an NC control button instead of NO (2-7).
  • M
    melinda81Sep 9, 2025
    Why does my CAME VER12 Gate Opener start too slowly?
    • S
      Steven EscobarSep 9, 2025
      If your CAME Gate Opener starts too slowly, eliminate all mechanical friction, check the door balancing and check the tautness of the belt/chain.
  • M
    maria45Sep 8, 2025
    Why does my CAME Gate Opener invert travel direction at the limit switch?
    • R
      richlauraSep 8, 2025
      If your CAME Gate Opener inverts the travel direction at the limit switch, check the proper direction of the door travel. Also, eliminate any mechanical friction and check the door balancing.
  • H
    harrisricardoAug 22, 2025
    What to do if my CAME Gate Opener neither opens nor closes?
    • L
      Levi SmithAug 23, 2025
      If your CAME Gate Opener isn't opening or closing, begin by checking the power supply and line fuses. Also, verify that the (1-2) NC safety contact is not open.
  • K
    Krista LangSep 5, 2025
    Why my CAME VER12 Gate Opener does not perform automatic closing?
    • W
      William PalmerSep 5, 2025
      If your CAME Gate Opener does not perform the automatic closing, check that the A.C.T. trimmer is not set to minimum and check the proper direction of the door travel.
  • E
    erinrodriguezSep 4, 2025
    Why is my CAME Gate Opener pushing weakly or inverting direction?
    • J
      jeremy11Sep 4, 2025
      If your CAME Gate Opener is pushing too weakly or inverting the direction of travel, try adjusting the sensitivity. Also, eliminate any mechanical friction, check the door balancing, and check the tautness of the belt/chain.
  • D
    Darren LaneSep 3, 2025
    Why does my CAME VER12 Gate Opener open but not close?
    • J
      John McdonaldSep 3, 2025
      If your CAME Gate Opener opens but doesn't close, the issue might be with the N.C. safety contact (2-C1) being open. In this case, check the proper direction of the door travel. You should also check the balancing of the overhead garage-door.
  • W
    William BaldwinSep 2, 2025
    Why is the photocell not working on my CAME Garage Door Opener?
    • C
      cbarkerSep 2, 2025
      If the photocell is not working on your CAME Garage Door Opener, it may be because The N.C. safety contact (2-C1) is open. Check proper functioning of the photocell.
  • J
    Janet DonaldsonSep 1, 2025
    What to do if my CAME Garage Door Opener closes but does not open?
    • V
      Valerie MartinSep 1, 2025
      If your CAME Garage Door Opener closes but does not open, check the balancing of the overhead garage-door.
  • A
    Amy YorkAug 30, 2025
    Why is the automatic closing not working on my CAME Garage Door Opener?
    • B
      Benjamin HawkinsAug 31, 2025
      If the automatic closing is not working on your CAME Garage Door Opener, check that the A.C.T. trimmer is not set to minimum and verify the proper direction of the door travel.

Summary

Premise

Before Installing

Checks and considerations before commencing the installation process.

Installing

Site Preparation and Safety

Demarcating the site, handling heavy units, and correct command placement.

System Compliance and Verification

Ensuring EN 12453 compliance and verifying safety device functionality.

General Instructions for Installing

Preliminary Checks

Electrical Connections

Command and Control Devices

Safety Devices

Programming

Selecting DIP Switches

Explanation of DIP switch functions for various programming modes.

Adjusting the Trimmers

Encoder Operation

Establishing the Closing and Opening Limit Switch Points

Programming the Partial Opening

Programming the Slow Start with Door Open (max. 50% of the door travel)

Programming the Closing Slow-Down (min. 600 mm from the final closing strike or max. 50% of the door travel)

Activating the Radio Control

Activating for the (2-7) Sequential Command

Activating for the (2-3 P) Partial Opening Command

Deleting All of the Memorized Transmitters

Releasing the Operator

Troubleshooting

CAME VER12 Specifications