p. 14 - Manual FA01317-EN - 01/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Command and control devices
1
STOP button (NC contact)
This stops the gate and excludes automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
2
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
3
Control device (NO contact)
PARTIAL OPENING function
PEDESTRIAN OPENING function
See Command 2-3P function.
4
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
5
Control device (NO contact)
OPEN-CLOSE function
OPEN-STOP-CLOSE-STOP function.
See control function 2-7.
6
Card reader
7
Transponder selector switch
8
Keypad selector
9
Antenna with RG58 cable
10 11 ES TS 1 2 3 3P 4 5 7 CX CY CZ
S1 GND
A B