-73-
Maintenance 5
Electrical System
Battery
Always stop engine and remove ignition key when servicing electrical system.
Shock hazard. Do not handle electrical components with wet hands.
Never charge battery when the uid level is below "lower level" line. Charging
battery with insufcient uid may shorten battery life or cause an explosion.
Battery fluid (diluted sulfic acid) is corrosive and causes severe burns. Be
extremeley cautious when handling battery fluid. If battery fluid is spilt on
clothes, immediately rinse with plenty of water. If spilt on skin or in an eye,
immediately rinse with plenty of water and promptly consult a physician.
Explosion hazard. Keep open flame or spark away from battery. Hydrogen
gas generated during charging is extremely explosive.• Never ll battery uid
beyond "upper level" line. Battery uid may spill and cause damage to machine
or injury to person.
Always disconnect (-) terminal rst, and connect (+) terminal rst. Disconnecting
or connecting in the opposite order may cause a short circuit.
When installing battery, make certain to connect (+) and (-) terminals to their
original positions. Avoid contact between terminals and other surrounding
parts.
10. Reinstall lower rear cover, engine hood, and
bumper.