-49-
Troubleshooting
6
Troubleshooting
• If any malfunction or abnormal condition is found, immediately stop using the
machine and take an appropriate measure according to the Troubleshooting chart
below. If the malfunction or abnormal condition is not listed in the chart, or the
suggested measure does not solve the problem, consult with your CANYCOM
representative.
• Some corrective measures listed below require special knowledge and/or
equipment. Please contact your CANYCOM representative in such a case.
Area Malfunction Possible Cause Corrective Measure Ref.
Engine
Engine does not start
(starter does not turn -
Electric start model only.)
Safety switch is
functioning.
→Make sure drive clutch
is in [Stop] position,
and push to turn
main switch to [Run]
position.
Page 17
Safety switch is
malfunctioning or needs
adjustment.
→Please contact
your CANYCOM
representative.
Engine does not start, or
is difcult to start.
Out of fuel. →Fill fuel. Page 14
Engine is ooded (too
much fuel fed into the
engine).
→Wait and restart.
Fuel valve lever is closed →Open fuel valve lever. Page 17
Poor ignition due to a
problem with spark plug.
→Clean or replace spark
plug.
Page 38
Other (other than the
above).
→Follow the instructions
in "Starting" to restart.
If problem persists,
please contact
your CANYCOM
representative.
Page 16