SETUP
Your ProDoc Series Scale has been pre-configured at the factory and should not require
changes for use in most applications. However, if the factory settings do not meet the
requirements of your operation, the following describes the setup process for your scale.
To Enter Setup
1. With the scale off, press and hold the ZERO key and then press the ON/OFF key.
2. The display will turn on all digits, show the software version for a few seconds and then
change to show Unit_ (where _ is the current setting).
3. Release all keys.
4. The scale is now ready for setup.
IMPORTANT! When a prompt and value displayed are acceptable, press the
BMI HEIGHT/ENTER key to save the setting and proceed to the next prompt. To
change a setting, press the RECALL or STORE keys to select a new value
and then press the BMI HEIGHT/ENTER key to save the new setting and advance
to the next prompt.
UNIT_ U
nit Setting
If the value displayed is acceptable, press the
BMI HEIGHT/ENTER key and proceed to the next
prompt. Otherwise, press the RECALL or STORE keys to select a new value and then
press the BMI HEIGHT/ENTER key to save it and proceed to the next prompt.
1 = Pounds Only 2 = Kilograms Only
3 = Pounds/Kilograms 4 = Kilograms/Pounds
NOTE! If 1 or 2 (Pounds only or Kilograms only) are selected, the UNITS key will be disabled.
ASH__ Automatic Shutoff
If the value displayed is acceptable, press the
BMI HEIGHT/ENTER key and proceed to the
next prompt. Otherwise, press the RECALL or STORE keys to select a new value
(from 00 to 9 minutes in 1 minute increments) and then press the
BMI HEIGHT/ENTER key to
save it and proceed to the next prompt.
NOTE! Selecting 00 disables the automatic shutoff feature.
SLP__ Sleep Mode
If the value displayed is acceptable, press the
BMI HEIGHT/ENTER key. Otherwise, press the
RECALL or STORE keys to select a new value (from 00 to 9 minutes in 1 minute
increments) and then press the BMI HEIGHT/ENTER key.
NOTE! Selecting 00 disables the sleep mode feature.
Once the BMI HEIGHT/ENTER key has been pressed at the Sleep Mode prompt, all Setup
Process settings (current or new values) will be saved and the Setup Process will be finished.
The display will show off and then shut the scale off.
NOTE! When you have finished changing Setup, the configuration counter will be
increased by one.
0044-M340-O1 Rev C ProDoc Series
26