Faults and system events
   
 
 
 
Carrier Connect™ Wi-Fi Thermostat 33CONNECTSTAT43FX    CARRIER CORPORATION ©2021  
Installation Guide    All rights reserved 
  51 
 
The faults and system events are displayed in the home and dormant screen banners. Faults and system events 
include: 
•  Startup  
•  Software Update Events 
•  Power Cycle Events 
•  Parameter Out-of-Range Events 
•  Server Connectivity Events 
•  Non-Volatile Memory Faults 
•  Temperature Faults  
 
The Faults and System events display in the banner while fault condition exists. You can see a history of the faults 
and system events in Carrier Connect mobile app under Alerts. The history is comprised of the 5 most recent 
logged items, with the most recent event being listed at the top.   
 
Fault becomes active when main thermistor (P102 or RT1) reads > 100°F. 
Fault is cleared when temperature <= 99°F.  
When this fault occurs, the thermostat uses the temperature reading from the 
temperature/humidity sensor as the space temperature. 
Fault becomes active when main thermistor (P102 or RT1) reads < 39°F. 
Fault is cleared when temperature >= 4°F.   
When this fault occurs, the thermostat uses the temperature reading from the 
temperature/humidity sensor as the space temperature. 
Remote temperature > 122°F; only flagged if remote sensor set to use as 
indoor temperature (REMOTE SENSOR setting set to INDOOR or AVERAGE) 
Remote temperature = 0°F; only flagged if remote sensor set to use as indoor 
temperature (REMOTE SENSOR setting set to INDOOR or AVERAGE) 
If the mode is cooling (Cool or Auto operating in Cool), the space temperature 
is greater than the cool setpoint plus the Maximum Setpoint Error and this 
condition exists for the number of minutes specified by the INDOOR TEMP 
FAULT INHIBIT time.  
If the mode is heating (HEAT, EHEAT or AUTO operating in HEAT), the space 
temperature is less than the heat setpoint minus the Maximum Setpoint Error 
and this condition exists for the number of minutes specified by the INDOOR 
TEMP FAULT INHIBIT time. 
Humidity sensor timed out 
•  humidity reading is > 99% 
•  humidity        reading is 0%. 
Humidity reading is > 90%