1 Network Installation
5
1.3.3 Scale Master Ethernet Connection without PC
Master
Slave Slave Slave Slave
HUB
NOTE: Only 32 scales can be connected in this method.
1. Scale number(for master) : 1
2. Scale number(for slave) : 2~32
3. PC master setting : No (refer to Error! Reference source not found. Error! Reference source not
found.)
4. Ethernet(10BaseT) SPEC
maximum segment length : 100 meter (328 feet)
media : Unshielded twisted-pair cable - Note
topology : star
Note : Scales(and other network devices) can be adversely affected by Electro-Magnetic
Interference(EMI). If the network cables must be run in proximity to strong sources
of EMI(Fluorescent light fixtures, AC motors, Air conditioning or Refrigeration compressors).
We STRONGLY recommend that shielded CAT 5 cable be used.