7. lnstallation
Load Cell Connection
Connect load cell connector to load cell port which is in the backside of indicator.
Note: Wire color can be different depending on the manufacturer or Load cell’s model
PIN COLOR PIN COLOR
1 (EXC+) RED 5(SHIELD) SHIELD
2 (EXC-) WHITE 6 (SEN+) BROWN
3 (SIG+) GREEN 7 (SEN-) BLACK
4 (SIG-) BLUE