43
12. How to use
12 - 1. HOW to SET the Original Number (Product ID) of Goods
STEP VFD DISPLAY and KEY INPUT PLATFORM DESCRIPTION
1 0kg Empty
2 1500kg Goods(Iron) Weight(1500kg)
3
Press [G/N] key for 2~3 seconds.
Display : “CodE=z LiM=t tArE=g”
201
Display : “On” -> “ID” 200
“COdE”
4
Press [ZERO] key and input 10
201
Input product ID 200
Input ID(=10) of iron
5 Press [ENTER] key Goods(Iron)
Show the ID of goods
Display the weight
Note 1. The ID of goods can be from 0 to 19.
12 - 2. HOW to INPUT the Value of Maximum and Minimum
STEP VFD DISPLAY and KEY INPUT PLATFORM DESCRIPTION
1 0.0kg Empty
2 150.0kg Goods(Iron)
3
Press [G/N] key for 2~3 seconds
Display : “CodE=z LiM=t tArE=g”
4
Press [TARE] key and then
display “HI”
5 Input the value of 1,000 Iron Maximum : 100.0kg
6
If it’s displayed the “LO”,
Input the value of 900.
Iron Minimum : 90.0kg
7 Press [ENTER] key Iron
It is input the Max. and
Min. value in this ID
Note 1. If the weight is larger than maximum, display “HI”.
If the weight is smaller than minimum, display “LO”.
If the weight is between maximum and minimum, display “OK”.
It is possible for F06 to set 2 (checker).