4
12 - 3. HOW to INPUT the VALUE OF TARE DIRECTLY
STEP VFD DISPLAY and KEY INPUT PLATFORM DESCRIPTION
1 Press [TARE] key for 2~3 seconds Empty
2
It’s displayed “tArE = z” “t-id = t”,
press [ZERO] key
Empty
3
Input the value of tare which you know
already with key
4 Press [ENTER] key and exit
12 - 4. HOW to INPUT the VALUE OF TARE with ID
STEP VFD DISPLAY and KEY INPUT PLATFORM DESCRIPTION
1 Press [ TARE ] key for 2~3 seconds Empty
2
It’s displayed “tArE = z” “t-id = t”,
press [TARE] key
Empty
3
Set the id what you want to
press [ G / N ] key.
4
If the step 2 is displayed,
press [ZERO] key
5 Input the value of tare & press [ENTER]
6 Repeat from step 2 to step 5 if you want
7 Press [ENTER] key and exit
12 – 5. HOW to READ the VALUE OF TARE with ID
STEP VFD DISPLAY and KEY INPUT PLATFORM DESCRIPTION
1 Press [TARE] key for 2~3 seconds Empty
2
It’s displayed “tArE = z” “t-id = t”,
press [TARE] key.
Empty
3
Input the ID which you want with key
& press [ENTER] keu
4 Press [ENTER] key and exit