33
SELECT LIMIT MODE
KEY FUNCTION DISPLAY VAL. DESCRIPTION
Select 0 or 1 0 Not use
1 Checker mode
ENTER
Save &
Go to F07
F06
2 Limit mode
UNIT Save & Exit
Save & go to Normal Mode
[ CHECKER MODE ]
Weight
Comm
Signal
(Low Limit) (High Limit)
0 kg 50 kg 100 kg
Display
ZERO
ON
OFF
LOW
ON
OFF
HIGH
ON
OFF
OK
ON
OFF
Note 1. All outputs are generated regardless of stable state.
[LIMIT MODE ]
Weight
Comm
Signal
(Low Limit) (High Limit)
0 kg 50 kg 100 kg
Display
ZERO
ON
OFF
LOW
ON
OFF
HIGH
ON
OFF
OK
ON
OFF
Note 1. OK signal is output when the state is stable only.