DISTRIBUTION SYSTEMS - HIGH-FLOW HYDRAULIC POWER SYSTEM
13. Disconnect the fuel shutoff solenoid connector.
(Photo is for reference only.)
BD04D010 2
14. Turn the engine over for 30 seconds to allow
hydraulic o
il from the reservoir to ow into the High
Flow Pump. Reconnect the fuel shutoff solenoid
connector.
15. Start an d run the engine at low idle for 2 to 5 minutes
and c heck for any leaks.
16. Stop the engine.
17. Check the hydraulic oil level in the reservoir and
add hydraulic oil as required. Reservo ir - Fillin g
(A.10.A.22 - F.60.A.10)
1 04/05/2005
A.16.A / 20